Current time in Korea 16:28 Mar 29 (Fri) Year 2024 KCS KCS Publications
KCS Publications
My Journal  Log In  Register
HOME > Search > Browsing(JKCS) > Archives

Journal of the Korean Chemical Society (JKCS)

ISSN 1017-2548(Print)
ISSN 2234-8530(Online)
Volume 53, Number 1
JKCSEZ 53(1)
February 20, 2009 

 
Title
Determination of Cd(II) after Preconcentration onto Microcrystalline p-Dichlorobenzene Loaded with 2-Mercaptobenzothiazole

2-Mercaptobenzothiazole이 내포된 p-Dichlorobenzene 미세결정으로 예비농축시킨 후 Cd(II) 정량
Author
Ju Im Yoon, Hee Seon Choi*

윤주임, 최희선*
Keywords
예비농축, p-Dichlorobenzene, 2-Mercaptobenzothizole, Cd(II) , Preconcentration, p-Dichlorobenzene, 2-Mercaptobenzothizole, Cd(II)
Abstract
실제 시료에 들어있는 흔적량 Cd(II)를 2-mercaptobenzothiazole이 내포되어 있는 미세결정 p-dichlorobenzene에 예비농축시킨 후 정량하는 감도좋은 방법을 개발하였다. 시료 용액의 pH, 킬레이트제 2-mercaptobenzothiazole의 양, 흡착제 p-dichlorobenzene-2-MBT의 양 그리고 시료 용액의 흐름속도 등 여러 실험조 건을 최적화하였다. 여러 공존이온에 대한 방해효과를 조사하였는데 다른 이온들보다 Cu(II)가 비교적 심하게 방해를 하였다. 그러나 Cu(II)에 의한 방해는 시료용액의 tartrate 이온의 농도를 0.01 M이 되게 하든지 또는 0.20 g의 p-dichlorobenzene에 내포된 2-mercaptobenzothiazole의 양을 0.08 g에서 0.12 g이 되게 하면 충분히 없앨 수 있었다. 이 방법에 의해 얻어진 직선 감응범위, 상관계수(R2) 및 검출한계는 각각 0.5-30 ng mL-1, 0.9962, 및 0.39 ng mL-1로서, p-dichlorobenzene을 흡착제 매질로 이용하여 매우 좋은 결과를 얻었다. 이 방법 을 실제 시료에 적용할 수 있을지를 확인하기 위해 수용액 시료(폐수, 시냇물, 그리고 저수지물)와 플라스틱 시료 에 응용하였다. 회수율은 93-104% 정도였으며, ICP-MS를 이용하여 얻은 값과 이 방법으로 얻은 값은 F 시험법 에 의하면 95% 신뢰수준에서 차이가 없는 것으로 나타났다. 실험 결과들로부터 이 방법은 여러 실제 시료에 들 어있는 Cd(II)을 농축 정량하는데 응용할 수 있음을 알 수 있었다.

A sensitive technique for the determination of trace Cd(II) in various real samples after preconcentration onto microcrystalline p-dichlorobenzene loaded with 2-mercaptobenzothiazole was developed. Several experimental conditions such as the pH of the sample solution, the amount of chelating agent 2-mercaptobenzothiazole, the amount of adsorbent p-dichlorobenzene-2-MBT, and the flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. Cu(II) interfered with more seriously than any other ions. However, the interference by Cu(II) could be overcome sufficiently by adjusting tartrate ion concentration to be 0.01M or by controlling the amount of 2-mercaptobenzothiazole contained in 0.20 g p-dichlorobenzene to be 0.12 g. The dynamic range, the correlation coefficient (R2) and the detection limit obtained by this proposed technique were 0.5~30 ng mL-1, 0.9962, and 0.39 ng mL-1, respectively. Thus, good results were obtained by the use of p-dichlorobenze as adsorbent matrix. For validating this proposed technique, the aqueous samples(wastewater, stream water, and reservoir water) and the plastic sample were used. Recovery yields of 93~104 % were obtained. By F test, these measured data were not different from ICP-MS data at 95 % confidence level. Based on the results from the experiment, it was found that this proposed technique could be applied to the preconcentration and determination of Cd(II) in various real samples.

Page
27 - 33
Full Text
PDF